Rev. 1.0 / Oct. 2010 17
AC & DC Operating Conditions
Recommended DC Operating Conditions
Notes:
1. Under all conditions, VDDQ must be less than or equal to VDD.
2. VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together.
AC & DC Input Measurement Levels
AC and DC Logic Input Levels for Single-Ended Signals
AC and DC Input Levels for Single-Ended Command and Address Signals
Notes:
1. For input only pins except RESET
, Vref = VrefCA (DC).
2. Refer to “Overshoot and Undershoot Specifications” on page 30.
3. The ac peak noise on V
Ref
may not allow V
Ref
to deviate from V
RefCA(DC)
by more than +/-1% VDD (for
reference: approx. +/- 15 mV).
4. For reference: approx. VDD/2 +/- 15 mV.
Recommended DC Operating Conditions
Symbol Parameter
Rating
Units Notes
Min. Typ. Max.
VDD
Supply Voltage
1.425 1.500 1.575 V 1,2
VDDQ
Supply Voltage for Output
1.425 1.500 1.575 V 1,2
Single Ended AC and DC Input Levels for Command and Address
Symbol Parameter
DDR3-800/1066/1333/1600
Unit Notes
Min Max
VIH.CA(DC100) DC input logic high Vref + 0.100 VDD V 1
VIL.CA(DC100) DC input logic low VSS Vref - 0.100 V 1
VIH.CA(AC175) AC input logic high Vref + 0.175 Note2 V 1, 2
VIL.CA(AC175) AC input logic low Note2 Vref - 0.175 V 1, 2
VIH.CA(AC150) AC Input logic high Vref + 0.150 Note2 V 1, 2
VIL.CA(AC150) AC input logic low Note2 Vref - 0.150 V 1, 2
V
RefCA(DC
)
Reference Voltage for ADD, CMD inputs 0.49 * VDD 0.51 * VDD V 3, 4